Configure: QMX3.P87 (PrphDev - subsystem-specific extension)

"Configure: QMX3.P87" is a subsystem-specific extension of "Peripheral device" (PrphDev) objects.

✳ Indicates a Siemens proprietary property.

Backlight timeout

 

 

"Backlight timeout" defines the amount of time that the backlight stays on after an operation. If there is no activity for the defined amount of time, the backlight turns off.

Range: 00:03...120:00 mm:ss

Backlight brightness

 

 

"Backlight brightness" defines the brightness of the backlight during active use.

Range: 0...100 %

Enable key beep

 

 

"Enable key beep" defines whether pressing a key should be accompanied by a short beep.

Yes

A short beep sounds when a key is pressed.

No

There is no sound when a key is pressed.

Area 1 text display time

 

 

"Area 1 text display time" defines the scrolling rate for text displayed in Area 1 of the screen. After the display time has elapsed, new text displays in Area 1 of the screen.

Units: 1/10 of a second

Range: 5 through 30

Setpoint display time

 

 

"Setpoint display time" defines the amount of time that the setpoint value displays. After the display time has elapsed, an average value displays.

Units: 1/10 of a second

Range: 5 through 3600, default 100 (10 sec.)

Air volume flow units (SI)

 

 

"Air volume flow units (SI)" defines the SI units used when displaying airflow values. This field is not active if US units are selected for the overall device (ActiveUnitSet).

m3/h

cubic meters per hour

l/s

liters per second

Enable automatic sash positioning

 

 

"Enable automatic sash positioning" defines:

Yes

Enables Key_8 to be used to activate the sash positioning device. The 'close the sash' icon appears next to Key_8.

No

Key_8 has no function. The 'close the sash' icon is not displayed next to Key_8.

Enable fume hood integrated light

 

 

"Enable fume hood integrated light" defines:

Yes

Enables Key_4 to be used as a light switch. The 'light bulb' icon appears next to Key_4.

No

Key_4 has no function. The 'light bulb' icon is not displayed next to Key_4.

Enable operation: Green leaf

 

 

"Enable operation: Green leaf" defines if the "Green leaf" LED indicates if the conditions for the energy efficiency state are fulfilled and if the user can reset the application to energy efficient parameter values.

Yes

The "Green leaf" LED indicates if the conditions for the energy efficiency state are fulfilled and the user can reset the application to energy efficient parameter values.

No

The "Green leaf" LED does not indicate if the conditions for the energy efficiency state are fulfilled and the user cannot reset the application to energy efficient parameter values.

Enable fume hood operation, mode off

 

 

"Enable fume hood operation, mode off" defines if the user is allowed to set fume hood operation to off.

Yes

The user is allowed to set fume hood operation to off.

No

The user is not allowed to set fume hood operation to off.

Enable fume hood operation, mode auto

 

 

"Enable fume hood operation, mode auto" defines if the user is allowed to set fume hood operation to auto mode.

Yes

The user is allowed to set fume hood operation to auto mode.

No

The user is not allowed to set fume hood operation to auto mode.

Enable fume hood operation, mode low

 

 

"Enable fume hood operation, mode low" defines if the user is allowed to set fume hood operation to low.

Yes

The user is allowed to set fume hood operation to low.

No

The user is not allowed to set fume hood operation to low.

Enable fume hood op., mode medium

 

 

"Enable fume hood op., mode medium" defines if the user is allowed to set fume hood operation to medium.

Yes

The user is allowed to set fume hood operation to medium.

No

The user is not allowed to set fume hood operation to medium.

Enable fume hood operation, mode high

 

 

"Enable fume hood operation, mode high" defines if the user is allowed to set fume hood operation to high.

Yes

The user is allowed to set fume hood operation to high.

No

The user is not allowed to set fume hood operation to high.