QMX2.P33, P43 template properties
The listed properties are displayed in the QMX2 templates editor > Inspector window > Properties tab when the templates is selected in the Project tree.
Marked properties ( 1) , 2) ) belong to a subsystem-specific extension. If the corresponding subsystem-specific extension is enabled, it overwrites the selected QMX2 template properties. As a precondition the property in the QMX2 template must be enabled.
General
Property | Description | Default value |
|---|---|---|
Template name | Automatically generated name. Read only. | Depends on other settings. |
Device type | Device type. Read only. | Depends on other settings. |
Version | Version of the offline engineered program for the automation station. Read only. | Depends on other settings. |
Display configuration
Which properties can be configured, depends on the device type.
Display item | Description |
|---|---|
| Indicates that the room operator unit is locked by the system. QMX2 interface: LockOpRu Application function: Room coordination |
| Currently not used. QMX2 interface: ImportInfo, Info |
|
Property | Description | Default value |
|---|---|---|
Room climate operating mode 1) | Room climate operating mode defines if the present operating mode is displayed.
If the application function supports an operating mode selection then the key 7 is activated. QMX2 interface: RClmOpModIn, RClmOpModRu Application function: HVAC user request
|
|
Presence 1) | Presence defines how the user can influence the room operating mode, using key 8.
|
|
Window contact 1) | Window contact enables or disables the indication that a window is open. If a window is open, the connected window switch is active. QMX2 interface: WndContRu Application function: HVAC user request
|
|
Heating/cooling state 1) | Heating/cooling state enables or disables the display of the plant state. QMX2 interface: HCStaRu Application function: HVAC user request
|
|
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
| ||
|
|
|
Property text | Description | Default value |
|---|---|---|
Room temperature | Room temperature defines if the room temperature is measured and reported. QMX2 interface: TR Application function: HVAC, for example Vav01.
|
|
Change of value, COV | Change of value, COV defines the change in the process value that triggers the sending of the process value. Unit: [K] | 0.2 |
Heartbeat | Heartbeat defines the time interval to report the process value if the value did not change or the change was smaller than the Change of value, COV. Range: | 120 |
Minimum repetition time | Minimum repetition time defines the minimal time interval before the next process value can be sent. Range: | 10 |
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Temperature display 1) | Temperature display defines which temperature values can be displayed. QMX2 interface: TRRu, TOaRu Application function: HVAC user request
|
|
Temperature unit | Temperature unit defines the unit for the display of the actual temperature and the temperature setpoint.
|
|
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Setpoint shift 1) | Setpoint shift defines if the temperature setpoint or the shift of the temperature setpoint is displayed and if the user can change either. QMX2 interface: SpShftIn, PrSpShftRu, PrSpRu Application function: HVAC user request
|
|
Type | Type defines how the shift in the temperature setpoint is displayed.
|
|
Increment | Increment defines the value by which the setpoint changes, each time the key is pressed. Range: | 1 |
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Relative room humidity | Relative room humidity defines if the relative room humidity is measured and reported. QMX2 interface: HuRelR Application function: HVAC user request
|
|
Change of value, COV | Change of value, COV defines the change in the process value that triggers the sending of the process value. Unit: [%] | 2 |
Heartbeat | Heartbeat defines the time interval to report the process value if the value did not change or the change was smaller than the Change of value, COV. Range: | 900 |
Minimum repetition time | Minimum repetition time defines the minimal time interval before the next process value can be sent. Range: | 10 |
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Relative humidity display 1) | Relative humidity display defines which relative humidity values can be displayed. QMX2 interface: HuRelRRu, HuRelOaRu Application function: ROpUn
|
|
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Relative humidity setpoint 1) | Relative humidity setpoint defines if the relative humidity setpoint is displayed and if the user can change it. QMX2 interface: SpHuRelRIn, SpHuRelRRu
|
|
Increment | Increment defines the value by which the relative humidity setpoint changes, each time the key is pressed. Range: | 1 |
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Air quality display 1) | Air quality display defines which air qualities can be displayed. QMX2 interface: AQualRRu, AQualRIndRu Application function: VAV plant
|
|
Air quality text display 1) | Air quality text display defines how the air quality is displayed.
|
|
Room air quality ind. | Room air quality ind. defines if the current air quality level is written to the BACnet object AQualRIndRu and if the information can be used by other devices e.g. QMX3.P36.
|
|
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
| ||
|
|
|
Property | Description | Default value |
|---|---|---|
Air quality setpoint 1) | Air quality setpoint defines if the air quality setpoint is displayed and if the user can change it. QMX2 interface: SpAQualRIn, SpAQualRRu
|
|
Increment | Increment defines the value by which the air quality setpoint changes, each time the key is pressed. Range: | 100 |
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
|
Property | Description | Default value |
|---|---|---|
Fan speed 1) | Fan speed defines if the fan speed is displayed and if the user can change the fan speed. QMX2 interface: FanSpdIn, FanSpdRu, FanOpIn Application function: Fan coil plant
|
|
Number of stages 2) | Number of stages defines the type of speed control of the connected fan.
|
|
Rapid ventilation 2) | Rapid ventilation defines if the user can start rapid ventilation. QMX2 interface: RpdVntIn, RpdVntRu Application function: VAV plant
|
|
1) The subsystem-specific extension "Configure: QMX2.P33/43" of the BACnet object Peripheral device object (PrphDev) allows to later configure the property value. Configure: QMX2.P33/43 (PrphDev - subsystem-specific extension)
2) The subsystem specific extension "KNX PL-Link: FSA" of the BACnet object Analog process value object (APrcVal) allows to commission the property value later. KNX PL-Link: FSA (APrcVal - subsystem-specific extension)
|
Property | Description | Default value |
|---|---|---|
Return to default display | Return to default display defines the time before the display returns from the presently active page to the default page (see Default display). Range: | 60 |
Backlight brightness | Backlight brightness defines the brightness of the backlight. Range: | 60 |
Timeout for backlight | Timeout for backlight defines the time before the backlight is turned of after the last operation of a key. Range: | 15 |
Default display | Default display defines which page is displayed after the 'Return to default display' time has passed.
|
|
|
Property | Description | Default value |
|---|---|---|
Manual mode for operating mode | Sets the priority for the property. Range: | 13 |
Operation limit for operating mode | Sets the priority for the property. Range: | 13 |
Operation limit for presence button | Sets the priority for the property. Range: | 13 |
Operation limit for temporary comfort | Sets the priority for the property. Range: | 13 |
Operation limit for temperature setpoint | Sets the priority for the property. Range: | 13 |
Operation limit for air quality setpoint | Sets the priority for the property. Range: | 13 |
Operation limit for relative humidity setpoint | Sets the priority for the property. Range: | 13 |
Manual mode for fan speed | Sets the priority for the property. Range: | 13 |
Operation limit for fan speed | Sets the priority for the property. Range: | 13 |


Room (QMX2.P33, QMX2.P43)
: The present operating mode is displayed.
: The present operating mode is not displayed.
None: Key 8 has no function relating to the room operating mode. The user cannot influence the room operating mode.



1...900 [s]